Walkable skylight glass – triple‑laminated safety glass for pedestrian‑accessible roof glazing. SGP interlayer, anti‑slip frit, 500 kg/m² certified load capacity. Thickness: 25.5mm, 31.5mm, 33.5mm, 39mm+. Max size up to 3000×12000 mm. DIN 18008‑5, EN 13049, BS EN 1991‑1‑1 certified. Request FOB quote.

Walkable Skylight Glass | Walk‑on Glass for Skylight & Roof Glazing – Jumbo Glass

Walk‑on Glass for Skylight & Roof Glazing – Engineered for Pedestrian Access with Post‑Breakage Load Retention

Walkable skylight glass​ is a specialized, multi‑ply laminated glass system designed to support planned pedestrian traffic​ on overhead glazing surfaces – roof terraces, decks, atriums, and maintenance walkways where people walk, stand, or gather. Unlike standard skylight glass (which only supports maintenance loads of 0.74–1.5 kN/m²), walkable skylight glass is engineered to sustain uniform distributed loads (UDL) of 4.0–5.0 kN/m² and concentrated loads of 3.6–4.5 kN​ under normal use conditions.

For procurement managers and glazing contractors supplying rooftop terraces, sky decks, glass bridges, atriums with public access, observation platforms, and accessible roof gardens, specifying the correct walkable skylight glass is a life‑safety imperative. The glass must retain structural integrity even after fracture – which is why triple‑laminated SGP construction is the global standard.

💡 Why walkable skylight glass is specified:​ The global trend toward "accessible rooftops" – rooftop bars, gardens, observation decks, and terraces – has created surging demand for walkable overhead glazing. Building codes (DIN 18008‑5:2024, BS EN 1991‑1‑1, EN 13049:2023) now explicitly regulate walk‑on glazing. For glass exporters, walkable skylight glass commands a 80–150% premium over standard skylight glass and opens access to high‑value architectural projects.

1. Quick Specification

ParameterStandard Skylight GlassWalkable Skylight Glass​
Construction​Single or double plyTriple‑ply minimum (3 layers of glass + 2 interlayers)​
Interlayer​PVB (optional)SGP (SentryGlas®) mandatory for top ply​
Thickness Range​6–21.52 mm25.5–44.5 mm​
UDL Capacity​0.74–1.5 kN/m²4.0–5.0 kN/m²​
Concentrated Load​N/A3.6–4.5 kN​ (50×50mm contact)
Deflection Limit​L/100L/200​ (stricter)
Anti‑Slip Rating​Not requiredR10–R13 / PTV 36–60​
Post‑Breakage Load Retention​Partial (single laminated)Full (triple‑ply, remains walkable after top ply fracture)​
Max Panel Size​≤3300×13000 mm≤3000×12000 mm​
Glass Types​Clear, Low‑Iron, TintedClear, Low‑Iron, Tinted, Ceramic Frit

2. Walkable Skylight Glass Solutions

2.1 Residential Walkable Skylight

  • Description:​ Walk‑on glass for home roof terraces, decks, and garden roofs
  • Glass build‑up:​ 8T + 1.52PVB + 8T + 1.52PVB + 8T (25.5mm total)
  • UDL:​ 1.5–2.0 kN/m² | Concentrated:​ 2.0 kN
  • Anti‑slip:​ Sandblasted (PTV ~50) or ceramic frit dots (PTV ~45)
  • Best for:​ Private rooftop terraces, residential decks
  • Key benefit:​ Safe access to outdoor space without sacrificing daylight

2.2 Commercial Walkable Skylight

  • Description:​ Heavy‑duty walk‑on glass for shopping malls, offices, and public buildings
  • Glass build‑up:​ 10T + 2.28SGP + 10T + 2.28SGP + 10T (33.5mm total)
  • UDL:​ 4.0 kN/m² | Concentrated:​ 3.6 kN
  • Anti‑slip:​ Ceramic frit pattern (PTV ~55, R11)
  • Best for:​ Shopping mall atriums, office roof terraces, hotel poolsides
  • Key benefit:​ Public‑access rated with certified load capacity

2.3 Heavy‑Duty Walkable Skylight

  • Description:​ Maximum‑load walk‑on glass for industrial and extreme‑traffic applications
  • Glass build‑up:​ 12T + SGP + 12T + SGP + 12T (40mm+ total)
  • UDL:​ 5.0 kN/m² | Concentrated:​ 4.5 kN
  • Anti‑slip:​ Full‑surface ceramic frit (PTV ~60, R13)
  • Best for:​ Train stations, airports, stadium concourses, warehouses
  • Key benefit:​ Highest certified pedestrian load + extreme durability

2.4 Walkable Skylight with Thermal Insulation (IGU)

  • Description:​ Walk‑on glass combined with insulated glazing unit for energy efficiency
  • Glass build‑up:​ 10T+1.52SGP+10T+1.52SGP+10T + 16Ar + 8T Low‑E
  • UDL:​ 4.0 kN/m² | U‑value:​ ~1.1 W/m²K
  • Anti‑slip:​ Sandblasted pattern (PTV ~48)
  • Best for:​ Energy‑efficient buildings with accessible roofs
  • Key benefit:​ Walkability + thermal performance in one system

2.5 Glass Bridge / Skywalk Skylight

  • Description:​ Specialized walk‑on glass for elevated glass bridges and skywalks
  • Glass build‑up:​ 12T + 2.28SGP + 12T + 2.28SGP + 12T (44.5mm total)
  • UDL:​ 5.0 kN/m² | Concentrated:​ 4.5 kN
  • Anti‑slip:​ Custom acid‑etched pattern (PTV ~52, R11)
  • Best for:​ Architectural skywalks, museum bridges, observation decks
  • Key benefit:​ Monumental spans with transparent walking surface

2.6 Low‑Iron Walkable Skylight

  • Description:​ Ultra‑clear walk‑on glass for premium applications
  • Glass build‑up:​ 10T Low‑Iron + 1.52SGP + 10T Low‑Iron + 1.52SGP + 10T Low‑Iron
  • UDL:​ 4.0 kN/m² | VLT:​ ~85%
  • Anti‑slip:​ Clear ceramic frit dots (maintains transparency)
  • Best for:​ Luxury hotels, galleries, high‑end residences
  • Key benefit:​ Maximum clarity + walkability

3. Glass Configurations – Walkable Build‑Ups

3.1 Triple‑Ply Laminated Configurations (Minimum Standard)

Build‑UpTotal ThicknessUDLConcentrated LoadApplication
8T + 1.52PVB + 8T + 1.52PVB + 8T25.5 mm1.5 kN/m²2.0 kNDomestic (small panels ≤600mm)
10T + 1.52PVB + 10T + 1.52PVB + 10T31.5 mm2.0 kN/m²2.5 kNDomestic (standard)
10T + 2.28SGP + 10T + 2.28SGP + 10T33.5 mm4.0 kN/m²3.6 kNCommercial (standard)​
12T + 1.52SGP + 12T + 1.52SGP + 12T39.0 mm4.0 kN/m²3.6 kNCommercial (larger spans)
12T + 2.28SGP + 12T + 2.28SGP + 12T44.5 mm5.0 kN/m²​4.5 kN​Heavy‑duty / Public access​

3.2 Four‑Ply Configurations (Extreme Load / Long Spans)

Build‑UpTotal ThicknessUDLConcentrated LoadApplication
10T+1.52SGP+10T+1.52SGP+10T+1.52SGP+10T44.5 mm5.0 kN/m²4.5 kNExtreme traffic / long spans
12T+1.52SGP+12T+1.52SGP+12T+1.52SGP+12T51.0 mm5.0+ kN/m²4.5+ kNMonumental installations

3.3 SGP vs. PVB for Walkable Glass

PropertyPVB InterlayerSGP (SentryGlas®) Interlayer​
Tear strength​Baseline5× stronger​
Post‑breakage rigidity​Moderate – sags under load100× stiffer – remains walkable​
Edge stability​GoodExcellent​
Moisture resistance​GoodExcellent​
Minimum requirement (DIN 18008‑5)​Not permitted as sole interlayerMandatory for top ply​
Cost premium​Baseline+20–30%
⚠️ Critical standard requirement:​ DIN 18008‑5:2024 mandates that walk‑on glazing must be constructed with at least three glass plies, and the top ply must use SGP interlayer​ for post‑breakage rigidity. PVB alone is not permitted for the load‑bearing interlayer in walkable applications.

3.4 Why Triple‑Ply Is Mandatory

Failure ScenarioDouble‑Ply (2 layers)Triple‑Ply (3 layers)​
Top ply breaksRemaining single ply cannot support load​ → collapse riskMiddle ply + bottom ply continue to carry full UDL
Middle ply breaksN/A (no middle in 2‑ply)Top + bottom plies redistribute load
Bottom ply breaksTop ply sags, no redundancyTop + middle plies retain structural integrity
All three plies intactN/ADesigned safety factor ≥2.0​

4. Safety Performance – Walkable Overhead Glazing

4.1 Load Requirements by Building Type

Building TypeUDL RequirementConcentrated LoadReference Standard
Domestic​1.5 kN/m²2.0 kNBS EN 1991‑1‑1
Commercial​4.0 kN/m²3.6 kNBS EN 1991‑1‑1
Heavy‑Duty Commercial​5.0 kN/m²​4.5 kN​DIN 18008‑5:2024
DIN 18008‑5 (general)​≤5.0 kN/m²50×50mm contact areaDIN 18008‑5:2024

4.2 Deflection Limits

StandardDeflection LimitNote
DIN 18008‑5:2024​L/200​Stricter than standard glazing (L/100)
BS EN 1991‑1‑1​L/200Confirmed by UK National Annex
AS/NZS 2208​L/175Australian/NZ requirement

4.3 Residual Load Capacity After Breakage

Glass ConfigurationResidual Capacity After Top Ply BreakageStill Walkable?
Double‑ply PVB (8+8)~30% of original❌ No – unsafe​
Triple‑ply PVB (8+8+8)~60% of original⚠️ Marginal
Triple‑ply SGP (10+10+10)​≥80% of original​✅ Yes – safe for evacuation​
Four‑ply SGP≥85% of original✅ Yes – full safety margin​

4.4 Impact Performance

StandardTest MethodRequirement for Walkable Glass
EN 13049:2023​Soft & heavy body impactPass – no penetration, retention ≥Class 1
EN 12600​40 kg pendulum impactClass 1B1
BS EN 1991‑1‑1​Concentrated load (50×50mm)No fracture at design load
DIN 18008‑5:2024​Impact + residual capacityPass at +20°C and −20°C

4.5 Anti‑Slip Performance

TreatmentPTV (Wet)R‑Rating (DIN 51130)Light TransmissionBest For
Sandblasted (full)​~50R10–R11~70%Domestic, clean aesthetic
Sandblasted (pattern)​~45R10~80% (partial)Design‑focused projects
Ceramic frit (dots)​~45–55R10–R11~60–80% (coverage dependent)Commercial, customizable
Ceramic frit (full)​~60R12–R13~30% (opaque)Heavy‑duty, maximum grip
Acid‑etched (pattern)​~48R10–R11~75%Premium residential
Specialist anti‑slip glass​18–57R9–R11VariableCustom specifications
💡 Recommendation:​ For external walkable skylights exposed to rain, target PTV ≥45​ (R11 minimum). Full‑surface ceramic frit achieves PTV ~60 (R13) and is the most durable option – baked into the glass surface, it never wears off.

5. Thermal & Solar Performance

5.1 U‑Value (Walkable Glass as Part of IGU)

ConfigurationU‑Value (W/m²K)SHGCVLTBest For
25.5mm Triple (8+8+8) – single unit5.20.7578%Internal only
31.5mm Triple (10+10+10) – single unit4.80.7577%Internal only
33.5mm Triple SGP + 16Ar + 8 Low‑E1.10.3965%External walkable + thermal​
39mm Triple SGP + 20Ar + 10 Low‑E0.90.3562%Premium commercial
33.5mm Triple SGP + 16Ar + 8 Solar Control1.10.2535%Hot climate roofs

5.2 UV Protection

Glass ConfigurationUV Blockage
Triple laminated (PVB)>99%
Triple laminated (SGP)>99%
Triple + Low‑E coating>99%

5.3 Acoustic Performance

ConfigurationRw (dB)STC
25.5mm Triple (8+8+8 PVB)4241
33.5mm Triple (10+10+10 SGP)4544
33.5mm Triple SGP + IGU4847

6. Maximum Glass Size – Walkable Skylight Capability

Our Grenzebach tempering furnace, jumbo autoclave, and CNC processing line​ enable walkable skylight glass at sizes that most suppliers cannot match.

ParameterStandard Walkable GlassJumbo Walkable Glass​
Max Width≤1500 mm (for 31.5mm triple)≤3000 mm​
Max Height≤4000 mm≤12000 mm​
Max Area~6 m²~36 m²​
Glass Thickness25.5–44.5 mm25.5–51.0 mm
InterlayerPVB / SGPSGP (mandatory top ply)​
Anti‑SlipSandblast / FritSandblast / Frit / Acid‑Etch / Custom

6.1 Size vs. Load Capacity Matrix

Build‑UpThicknessMax Panel Width (at 4.0 kN/m²)Max Span
10T+1.52PVB+10T+1.52PVB+10T31.5 mm1200 mm1500 mm
10T+2.28SGP+10T+2.28SGP+10T33.5 mm1800 mm2200 mm
12T+1.52SGP+12T+1.52SGP+12T39.0 mm2200 mm2800 mm
12T+2.28SGP+12T+2.28SGP+12T44.5 mm2800 mm3500 mm
4‑ply SGP44.5–51.0 mm3000 mm4000 mm

6.2 Manufacturing Equipment

EquipmentSpecificationImpact on Walkable Quality
Grenzebach Tempering Furnace​Max 3300×20000mm; surface stress ≥95 MPaAll plies fully tempered to EN 12150‑1
Jumbo Autoclave​Max 3300×18000mm; computer‑controlledBubble‑free SGP bonding, zero delamination
CNC Processing​Max 3300×19000mm; ±0.3mm tolerancePrecision cut‑outs for drainage, anti‑slip patterning
Ceramic Frit Kiln​Max 3300×15000mm; 680°C sinteringPermanent anti‑slip surface, never wears off
Anti‑Slip Testing Lab​Pendulum Test (BS 7976‑2), Ramp Test (DIN 51130)Every batch certified for slip resistance

7. Glass Processing for Walkable Skylight Systems

7.1 Triple‑Ply Lamination Process

StepProcessQuality Check
1. Glass selectionAll plies fully tempered (≥95 MPa surface stress)Stress meter verification
2. Interlayer placementSGP between all plies (PVB optional for inner)Thickness gauge check
3. Pre‑laminationNip rollers, 50–60°C, air evacuationVisual inspection for bubbles
4. Autoclaving130–140°C, 10–12 bar, 60–90 minBond strength test (EN 14449)
5. Edge sealingSilicone or PVB edge tapeWater ingress test
6. Anti‑slip applicationCeramic frit sintering OR sandblastingPendulum test (PTV verification)

7.2 Edge Finishing

Edge TypeAppearanceBest ForNote
Polished​Glossy, transparentFrameless walkable skylightsRecommended​ – edges visible on roof
Flat Ground​Smooth matteFramed systemsAcceptable for concealed edges
Beveled​Angled decorativePremium residentialAvailable on jumbo panels

7.3 Anti‑Slip Surface Processing

MethodProcessDurabilityPTV RangeDesign Flexibility
Ceramic Frit (full)​Silk‑screen + kiln fire at 680°CPermanent (lifetime)​55–60Any colour, dot matrix, custom logos
Ceramic Frit (pattern)​Partial coverage silk‑screenPermanent​45–55Custom patterns, transparency maintained
Sandblasting (full)​CNC‑controlled abrasive blasting10+ years~50Uniform matte finish
Sandblasting (pattern)​Masked CNC blasting10+ years~45Custom designs
Acid Etching​Chemical surface treatment15+ years~48Smooth satin appearance
Specialist Anti‑Slip​Proprietary textured glass10+ years18–57 (R9–R11)Limited sizes (max ~2200×3100mm)
💡 Durability ranking:​ Ceramic frit > Acid etching > Sandblasting > Topical coatings. For external walkable skylights, ceramic frit is the only permanent solution​ – it is baked into the glass surface at 680°C and cannot peel, wear, or wash away.

7.4 Hole Drilling & Cut‑Outs

  • Must be completed before lamination
  • Diameter:​ 12–60 mm
  • Edge distance:​ ≥2× glass thickness (≥25mm for walkable glass)
  • Countersinking:​ Available for flush hardware
  • Drainage holes:​ Critical for external walkable skylights – water must not pool

7.5 Notching

  • For base shoe clearance and framing connections
  • Depth:​ 10–40 mm
  • Minimum distance from edge:​ ≥50 mm (walkable glass requires greater edge clearance)

7.6 Quality Assurance – Every Walkable Panel

TestStandardAcceptance Criteria
Dimensional inspection​ISO 9001±0.5 mm
Flatness inspection​EN 12150‑1±0.5 mm/m
Bond strength​EN 14449≥5 N/mm (T‑peel test)
Pendulum slip test​BS 7976‑2PTV ≥36 (wet)​ – certified per panel
Ramp slip test​DIN 51130R10 minimum​ (R11+ for external)
UDL load test​DIN 18008‑5 / BS EN 1991‑1‑1No fracture at design load
Concentrated load test​DIN 18008‑5No fracture at 3.6–4.5 kN (50×50mm)
Deflection measurement​DIN 18008‑5≤L/200 at design load
Residual capacity test​DIN 18008‑5:2024≥80% capacity after top ply breakage
Impact test (soft body)​EN 13049:2023Class 1 – no penetration
Heat soak test​EN 141794hrs @ 290°C, ≤0.01% breakage
Thermal cycle test​DIN 18008‑5:2024Pass at +20°C and −20°C

8. Applicable Glass Products

Each walkable skylight configuration links directly to our product pages for detailed specifications.

Walkable ConfigurationRecommended ProductLink
Triple‑ply SGP walkable glass​Jumbo Laminated Glass (SGP)View Product →
Walkable + Low‑E thermal​Jumbo Low‑E Glass + IGUView Product →
Walkable + Solar Control​Jumbo Reflective GlassView Product →
Low‑Iron walkable glass​Ultra Clear Tempered GlassView Product →
Glass bridge / skywalk​Jumbo Laminated Glass (SGP, 4‑ply)View Product →
Walkable IGU (thermal)​Jumbo Insulated GlassView Product →
Anti‑slip ceramic frit glass​Custom Ceramic Frit GlassView Product →
Jumbo walkable glass​Jumbo GlassView Product →

9. Standards & Certifications

StandardScopeApplicable To
DIN 18008‑5:2024​Walk‑on glazing – design & construction rulesPrimary standard for walkable skylights​
BS EN 1991‑1‑1​Actions on structures – general actions, imposed loadsUDL & concentrated load definitions
EN 13049:2023​Windows & pedestrian doors – soft/heavy body impactImpact safety for walkable glazing
EN 12600​Pendulum impact test – classificationGlass impact resistance
EN 12150‑1​Thermally toughened soda lime silicate glassAll tempered plies
EN 14449​Laminated glass – definition & descriptionTriple‑ply laminated construction
EN 14179​Heat soak test for tempered glassHST for all plies
BS 7976‑2​Pendulum test for slip resistanceAnti‑slip certification (PTV)
DIN 51130​Ramp test for slip resistanceR‑rating certification
EN 1279​Insulating glass units (EU)Walkable IGU configurations
EN 1873​Prefabricated rooflightsSkylight product certification
ANSI A326.3​Dynamic Coefficient of Friction (DCOF)US slip resistance standard
AS/NZS 2208​Safety glazing for buildingsAustralia/NZ markets
CE​European conformity markingEU market
CCC​China compulsory certificationChina market
ISO 9001​Quality management systemManufacturing process

Project References

ProjectCountryWalkable SolutionSizeCertified LoadAnti‑Slip
Rooftop Bar (Dubai)​UAE10T+2×SGP+10T+IGU Low‑E2400×1200 mm5.0 kN/m² UDLCeramic frit R12
Shopping Mall Atrium (Singapore)​Singapore10T+2×PVB+10T1800×900 mm4.0 kN/m² UDLSandblast R11
Hotel Pool Deck (Miami)​USA12T+2×SGP+12T+IGU3000×1500 mm5.0 kN/m² UDLFull frit R13
Museum Glass Bridge (Germany)​Germany12T+3×SGP+12T (4‑ply)3500×1200 mm5.0 kN/m² UDLAcid etch R11
Office Roof Terrace (London)​UK10T+2×SGP+10T+IGU Low‑E2000×1000 mm4.0 kN/m² UDLFrit dots R10
Observation Deck (Tokyo)​Japan12T+2×SGP+12T2800×1400 mm5.0 kN/m² UDLCeramic frit R12
Residential Sky Deck (Sydney)​Australia10T+2×SGP+10T1500×800 mm2.0 kN/m² UDLSandblast R10

10. Request Walkable Skylight Glass Quote

Submit your project requirements for a competitive FOB quotation and engineering assessment.

Required Information:

  • Application type:​ Rooftop terrace / Atrium / Glass bridge / Pool deck / Observation deck / Residential deck
  • Building type:​ Domestic / Commercial / Heavy‑duty commercial
  • Glass build‑up (if known):​ e.g., 10T+2×SGP+10T
  • Number of plies:​ 3 (standard) or 4 (extreme load)
  • Interlayer: SGP (mandatory top ply) / PVB (inner optional)
  • Glass thickness per ply: 8mm / 10mm / 12mm
  • UDL requirement:​ 1.5 / 2.0 / 4.0 / 5.0 kN/m²
  • Concentrated load requirement:​ 2.0 / 3.6 / 4.5 kN
  • Anti‑slip requirement:​ PTV target / R‑rating / DCOF
  • Anti‑slip method: Ceramic frit / Sandblast / Acid etch / Pattern
  • Frit coverage % (if ceramic): e.g., 30% / 50% / 100%
  • Dimensions (width × height × quantity per panel)
  • Span / support spacing
  • IGU required? Yes / No (if yes: Low‑E / Solar Control / Argon / Krypton)
  • Drainage requirements: Holes / Slots / Edge drainage
  • Building code jurisdiction: DIN 18008‑5 / BS EN 1991 / EN 13049 / AS/NZS / Other
  • Edge finish: Polished / Flat ground / Beveled
  • Processing: Holes, notches, cut‑outs (provide drawing)
  • Application: Residential / Commercial / Public / Industrial
  • Project location
  • Certifications required
  • Target delivery date
  • 📧 Email your specification to:​ tomron1688@gmail.com
  • 🌐 Or upload drawings at:​ www.jumbotemperedglass.com
  • Response time:​ Preliminary feasibility within 24 hours; detailed quotation with FEA load calculation within 48 hours.

11. Frequently Asked Questions

Q1: What makes walkable skylight glass different from standard skylight glass?

Walkable skylight glass is engineered for planned pedestrian traffic​ with UDL capacities of 4.0–5.0 kN/m², while standard skylight glass only supports maintenance loads (0.74–1.5 kN/m²). Walkable glass requires triple‑ply laminated construction with SGP interlayer and anti‑slip surface treatment.

Q2: Why is triple‑ply (three layers) mandatory?

DIN 18008‑5:2024 explicitly requires minimum three plies for walk‑on glazing. If the top ply breaks, the remaining two plies must continue to support the full design load. Double‑ply construction has no redundancy – a single fracture creates an immediate fall hazard.

Q3: What is the difference between SGP and PVB for walkable glass?

SGP is 5× stronger and 100× stiffer than PVB. After breakage, SGP‑laminated glass remains rigid and walkable​ (≥80% residual capacity), while PVB‑laminated glass sags significantly. DIN 18008‑5 mandates SGP for the top ply of walkable glazing.

Q4: What anti‑slip rating do I need?

For domestic interiors: R10 / PTV 36+. For external or wet areas: R11 / PTV 45+. For pool decks, rooftops in rainy climates, or heavy‑duty public access: R12–R13 / PTV 55+. Ceramic frit provides the most durable anti‑slip surface – it is baked into the glass at 680°C and never wears off.

Q5: Can walkable skylight glass be insulated (IGU)?

Yes. Walkable glass can be combined with a Low‑E insulated unit to achieve U‑values as low as 0.9 W/m²K while maintaining full walkability. The walkable laminated unit is positioned as the outer (walking) surface.

Q6: What is the maximum panel size for walkable skylight glass?

Up to 3000×12000 mm​ for 33.5mm triple‑ply SGP. Panel size is limited by load capacity – larger panels require thicker build‑ups or closer support spacing. We provide FEA calculations for every project.

Q7: Is heat soak testing required for walkable glass?

Yes – DIN 18008‑5:2024 requires residual capacity verification after thermal cycling. We heat soak test all tempered plies (290°C × 4 hours) to reduce nickel sulfide breakage to ≤0.01%, and perform residual capacity testing at +20°C and −20°C.

Q8: How is walkable skylight glass tested for slip resistance?

Every panel is tested using the Pendulum Test (BS 7976‑2)​ for PTV and the Ramp Test (DIN 51130)​ for R‑rating. Results are certified per panel and documented in the quality report accompanying each shipment.

Q9: What happens if someone walks on the glass when one ply is broken?

This is exactly why triple‑ply SGP construction is mandatory. Testing per DIN 18008‑5:2024 confirms that after the top ply is deliberately fractured, the remaining two SGP‑bonded plies retain ≥80% of the original load capacity​ – sufficient for safe evacuation.

Q10: What is the lead time for walkable skylight glass?

Standard configurations: 8–10 weeks (includes triple‑ply lamination, SGP autoclaving, anti‑slip processing, and full load testing). Custom sizes or complex anti‑slip patterns: 10–12 weeks.

12. Related Pages (Internal Link Cluster)

Within Skylight & Roof Glass Section

PProduct Pages (Cross‑Links)

Other Applications

0
Inquire for more cooperation or product information.
We will contact you within 1 working day, please check your email.
Walkable Skylight Glass – Walk‑on Glass for Skylight & Roof Glazing
Company Name
Name
Mail
Mobile phone
Message
Send

Tomron

We reply immediately
Welcome to our website. Ask us anything 🎉

Start Chat with: