English
Glass Partition Selection Guide:How to specify interior glass partitions — frameless office walls, conference rooms, demountable systems, glass office fronts, healthcare screens and shower enclosures. Tempered, laminated (PVB/SGP), acoustic and switchable (PDLC) configurations, 10–19mm thickness, STC 35–45dB, deflection and impact compliance.
Home / Resources / Selection Guides / Glass Partition Selection Guide
How to specify interior glass partitions — frameless office walls, conference rooms, demountable systems, glass office fronts, healthcare screens and shower enclosures. Tempered, laminated (PVB/SGP), acoustic and switchable (PDLC) configurations, 10–19mm thickness, STC 35–45dB, deflection and impact compliance.
Vertical interior glazingEN 12150 · EN 14449 · ASTM C1048Jumbo tempered up to 3300×20000mmHST 554°F × 4 hrs
A glass partition is a vertical or near-vertical interior glazed screen that divides a space without carrying structural load. Typical projects include open-plan office partitions, glass-fronted meeting rooms, executive offices, reception enclosures, healthcare and laboratory screens, hotel bathroom walls, shower enclosures, retail back-of-house glazing and demountable (relocatable) office systems.
A partition is not a bridge and not a canopy. A bridge carries pedestrians; a canopy is overhead; a partition stands upright and carries its own weight plus lateral loads — HVAC pressure differences, door slams, human impact and occasional cleaning loads. This changes the entire specification.
The defining rule: Because a partition is a vertical, non-trafficable screen, it does not face the concentrated point loads that govern walkable glass. Thickness is driven by panel height, lateral deflection, impact category and acoustic requirement — not by pedestrians. Most partitions are therefore far thinner than bridges: 10–19mm monolithic tempered or a 12.76–13.52mm laminate, versus the 30.76–44.76mm multi-ply SGP assemblies used for walkable floors.
Where partitions sit in the Selection Guide family: A canopy and a skylight are overhead glazing (distribution of wind, snow and self-weight); a bridge is walkable glazing under concentrated point loads (L/500–L/1000, 3-ply SGP). A partition is vertical, non-load-bearing and often acoustic-first — a different design world, covered on this page.
Glass partitions are governed by safety glazing, impact and acoustic rules rather than floor-load codes. The relevant checks differ by market, but the load and serviceability types are consistent:
Self-weight
The panel supports its own weight in the vertical plane; the frame and fixings transfer it to the slab and ceiling. Less demanding than a spanning floor panel.
Lateral load
Pressure differences across the partition, door-slam effects and human body impact. The governing lateral case for most interior panels.
Deflection
Commonly around L/60 of the panel height — far more relaxed than walkable glass (L/500–L/1000) because no one stands on the panel.
Acoustics
Often the primary design driver in offices — the partition is selected as much for privacy as for transparency.
| Standard | Market | Scope |
|---|---|---|
| EN 12150 | EU / UK | Thermally toughened (tempered) safety glass |
| EN 14449 | EU / UK | Laminated safety glass |
| EN 12600 | EU / UK | Pendulum impact test for flat glass |
| EN ISO 10140 | EU / UK | Laboratory measurement of sound insulation (STC/Rw) |
| ASTM C1048 | USA | Heat-treated flat glass (Kind FT) |
| ASTM C1172 | USA | Laminated architectural glass |
| ASTM E90 | USA | Laboratory measurement of airborne sound transmission |
| 16 CFR 1201 / ANSI Z97.1 | USA | Safety glazing in hazardous locations |
| AS/NZS 2208 | Australia / NZ | Safety glazing materials |
| Local building / fire code | All | Hazardous locations, fire rating, demountable-system approvals — confirm with the design team Acoustics is often the real driver: In an office, the question is rarely "will the glass hold?" — it is "can the next desk hear the meeting?" Partition selection therefore balances clarity, safety and STC, with the frame and ceiling plenum forming part of the acoustic system. |
A glass partition is typically a single monolithic tempered lite or a two-ply laminate, captured in a framing system at head, jamb and sill. Unlike a bridge panel, it does not need to be a multi-ply load-bearing slab.
Single lite (most common — frameless office partition): ┌──────────────────────────────────────────┐ │ Tempered lite (10 / 12 / 15 / 19mm) ← vertical glass ├──────────────────────────────────────────┤ │ Frame / channel at head, jamb and sill └──────────────────────────────────────────┘ Laminated option (impact / post-breakage / acoustic): ┌──────────────────────────────────────────┐ │ Ply (6 / 8 / 10mm) ← outer ply ├──────────────────────────────────────────┤ │ PVB / acoustic PVB interlayer (0.38–0.76mm) ├──────────────────────────────────────────┤ │ Ply (6 / 8 / 10mm) ← inner ply └──────────────────────────────────────────┘ Typical: 6+1.52PVB+6 = 12.76mm or 5+1.52PVB+5 = 10.76mm Switchable option: laminate with PDLC film between plies (opaque ↔ clear)
Why a partition is usually monolithic tempered: A vertical panel is not walking traffic and does not need the residual strength of a multi-ply SGP bridge assembly. Fully tempered glass (EN 12150 / ASTM C1048, surface stress ≥95 MPa) provides the required impact safety at a fraction of the thickness and cost. Laminate is specified where post-breakage retention, acoustic control or mandatory impact rating applies.
| Construction | Build-up example | Safety | Acoustics (STC) | Best for |
|---|---|---|---|---|
| Monolithic tempered | 10 / 12 / 15 / 19mm single lite | ✅ Tempered | ~35–38 | Standard office, general interior |
| Laminated (PVB) | 6+1.52PVB+6 = 12.76mm | ✅ Post-breakage retention | ~38–40 | Schools, healthcare, public buildings |
| Acoustic laminated (PVB) | 5+0.76AcPVB+5 / 6+0.76AcPVB+6 | ✅ Post-breakage retention | ~40–42 | Conference rooms, executive offices (recommended) |
| Double-glazed acoustic (system) | Two lites + framed cavity (with blind optional) | ✅ Tempered / laminated | ~43–48 | High-privacy boardrooms, phone rooms |
| Switchable (PDLC) laminate | Laminate with PDLC film between plies | ✅ Laminated | ~38–42 | Privacy-on-demand meeting rooms |
| Low-iron partition | Low-iron tempered or laminate | ✅ | ~35–40 | Premium clear interiors, showrooms Why laminated wins the impact-rated locations: In schools, hospitals, public circulation and any panel classified as a "hazardous location", a laminated ply (or tempered-and-laminated construction) keeps broken glass in place — removing the principal injury pathway. It is a modest upgrade over monolithic tempered and is increasingly specified as standard for commercial interiors. |
The table below is a preliminary design starting point for vertical, simply supported (frame-captured) panels under normal interior lateral loads. Final thickness must be confirmed by the frame-system supplier and a qualified designer against panel dimensions, impact category and local code.
| Application / panel height | Recommended thickness | Note |
|---|---|---|
| Cabinet / display / low screen | 6 – 10 mm | Small panels, limited exposure |
| Standard office partition, up to ~3m | 12 mm | Most common baseline |
| Frameless office wall, 2.7–3.6m | 12 – 15 mm tempered | Standard open-plan specification (recommended) |
| Tall floor-to-ceiling, >3.6m | 15 – 19 mm | Deflection control + handling |
| Doors & sidelights | 10 – 12 mm (tempered or laminated) | Higher impact category |
| Shower enclosure / wet area | 8 – 12 mm tempered | Confirm local safety glazing rules |
| Application | Recommended build-up | Overall thickness | Driver |
|---|---|---|---|
| Standard acoustic partition | 5+1.52PVB+5 | 10.76 mm | Sound + safety |
| Conference / healthcare / schools | 6+1.52PVB+6 | 12.76 mm | Impact + post-breakage + STC (recommended) |
| Premium acoustic | 6+0.76AcPVB+6 | 12.76 mm | Higher STC |
| High-impact / security | 8+1.52PVB+8 or thicker | 17.52 mm+ | Robustness Height, not span, is the variable: Partition thickness is governed by panel height, aspect ratio, edge capture (frame pocket depth), lateral load and deflection limit — not by a floor span. A tall narrow panel deflects differently from a short wide one. Provide the panel dimensions and frame detail with your RFQ; the frame system and glass thickness must be specified together. |
For office partitions, acoustic performance often matters more than structural capacity. The glass is only one part of the system — the frame, ceiling plenum, door and perimeter seals complete the sound path.
| Glass / system | Typical STC / Rw | Privacy level |
|---|---|---|
| Single 12mm tempered lite | ~35–38 dB | General speech audible |
| Acoustic laminate (asymmetric + AcPVB) | ~40–42 dB | Normal conversation reduced |
| Double-glazed system (2 lites + cavity) | ~43–48 dB | Confidential meeting privacy (recommended) |
| Double-glazed + integrated blind | ~45–50 dB | High privacy |
Glass partitions are a natural fit for jumbo tempered glass. A single oversize lite can form an entire floor-to-ceiling feature wall without a transom — cleaner lines, uninterrupted sightlines and a more open feel. Because most partitions are monolithic tempered (not a sealed IGU), they can use our full single-lite jumbo capacity.
| Capability | Jumbo Glass Group |
|---|---|
| Max jumbo tempered panel | 3300 × 20000 mm (11 × 65.6 ft) |
| Jumbo threshold | Width > 2440 mm and height > 3660 mm |
| Typical office partition panel | 1200–1800 mm wide × 2700–3600 mm tall |
| Typical thickness | 10–19 mm (monolithic) / 10.76–17.52 mm (laminate) |
| Max panel weight | Up to ~4,200 kg / 9,300 lbs per panel (thickness dependent) |
| Cutting accuracy | Bystronic CNC ±0.01″ (±0.25 mm) |
| Tempering uniformity | Grenzebach furnace ±9°F (±5°C) |
| Edge options | Polished / beveled / arrissed; flatness ≤0.004″/ft Why a partition uses the full 20000mm length (not the IGU limit): A skylight IGU is sealed and gas-filled, so handling and seal integrity cap it at 3300×12000mm. A glass partition is a monolithic tempered or two-ply laminated lite, limited only by the glass-making and handling envelope — our full 3300×20000mm applies. In practice, ceiling height and frame pocket depth usually govern before the glass-making limit does. When to go jumbo: If you want a transom-free floor-to-ceiling wall, a jumbo-height lite (up to 3300×6000mm+) eliminates the horizontal joint and gives a genuinely seamless interior. The frame must be engineered for the taller panel's deflection and lateral load, and the handling path (lift, crate, doorways) must be planned before production. |
| Item | Rule for interior partitions |
|---|---|
| Edgework | Polished, beveled or arrissed edges. Edge quality matters — the exposed perimeter is a visible design feature and a common break origin. |
| Frame capture | Adequate pocket depth at head, jamb and sill; setting blocks and clearance sized for panel weight and lateral load. |
| Deflection allowance | Design the frame for ~L/60 of panel height (or per project code); allow for glass self-weight and thermal movement. |
| Hardware / fittings | Clamps, patch fittings and door hardware specified for the glass thickness; never retrofit-drilled into tempered glass. |
| Drilling / notching | Completed on monolithic glass before tempering — never after. For laminated partitions, all cutting is done before lamination. |
| Seals & gaskets | Perimeter gaskets for acoustics and weather (wet areas); align with the acoustic-system design. Tempered glass cannot be field-modified: Holes, notches and cut-outs must be finalised before tempering. For retrofit or uncertain layouts, laminated glass offers more flexibility in some systems — but the lites themselves still cannot be cut after lamination. Confirm every opening and fitting location at order placement. |
| Step | Rule for partition glass |
|---|---|
| Cutting & edgework | Bystronic CNC ±0.01″; polished / beveled / arrissed edges. |
| Tempering | Fully tempered (EN 12150 / ASTM C1048), surface stress ≥95 MPa. |
| Lamination (if specified) | PVB or acoustic PVB, autoclave bonded; SGP only where structural residual strength is required. |
| Switchable film (optional) | PDLC film laminated between plies; wiring routed at edge per system design. |
| Heat soak test (HST) | 554°F (290°C) × 4 hours — recommended for critical / high-traffic / overhead panels to eliminate nickel sulphide (NiS) risk. |
| Edge sealing (laminates) | Perimeter sealant after lamination to protect the interlayer from moisture. Why HST is recommended for partitions: Most office partitions are not life-safety glass, so HST may be optional for a standard back-office panel. But for a flagship lobby, a panel above a reception desk, a large floor-to-ceiling lite or any overhead/adjacent-to-door panel, HST is the sensible specification — it forces NiS inclusions to fail in the factory, reducing field breakage risk to below 0.01%. Jumbo Glass Group records a post-HST breakage rate below 0.08%, supported by SGS batch reports, EN 12150 traceability and 20-year breakage insurance. |
① Location & use→② Hazardous / impact rating?→③ Tempered or laminated→④ Thickness (height/deflection)→⑤ Acoustic target (STC)→⑥ Frame / system→⑦ HST & edge finish→⑧ RFQ + drawing
| Step | Decision | Typical outcome |
|---|---|---|
| ① Location & use | Office / conference / healthcare / shower / retail | Sets code and acoustic baseline |
| ② Hazardous location? | Check local safety-glazing rules | Yes → tempered or laminated required |
| ③ Construction | Tempered vs laminated vs acoustic vs switchable | Laminated for impact/post-breakage |
| ④ Thickness | From panel height, aspect ratio, frame capture | 12mm standard; 15–19mm tall |
| ⑤ Acoustic target | STC required for privacy | Acoustic laminate or double-glazed system |
| ⑥ Frame / system | Demountable / stick / structural silicone | Frame + glass specified together |
| ⑦ HST & edge | Critical panel → HST; edge polished | Prevents field breakage |
| ⑧ RFQ | Dimensions, hardware, drawings, standard | Free simulation & quotation |
What is the difference between a glass partition and a glass bridge?
A glass bridge is a walkable, trafficable floor — it carries concentrated pedestrian point loads and is governed by life-safety rules. A glass partition is a vertical or near-vertical interior screen — it carries its own weight and lateral loads (wind from HVAC, door slam, human impact), not people. This changes everything: a partition is typically thinner (10–19mm), often monolithic tempered or a modest laminate, and deflection limits are around L/60 rather than the L/500–L/1000 demanded of walkable glass. Bridges need 3-ply SGP; most partitions do not.
Should an interior glass partition be tempered or laminated?
Where the local building code classifies the location as a "hazardous location" (large panels, doors, panels adjacent to doors, floor-to-ceiling glazing, panels subject to human impact), tempered or laminated safety glass is generally required — monolithic annealed glass is not acceptable. Laminated is preferred where post-breakage retention matters: schools, healthcare, public buildings, and any panel where glass falling into the room below is a concern. When in doubt, specify laminated — it costs modestly more and removes a major injury pathway. Confirm the exact requirement with the project's building official.
How thick is a typical glass office partition?
For a standard frameless office partition up to about 3m tall, 12mm tempered is the common baseline; 10mm is used for shorter panels and 15mm / 19mm for taller or wider spans and high-traffic areas. Acoustic laminates such as 10.76mm or 12.76mm are specified where sound control matters. The table in this guide is a preliminary starting point — final thickness must be confirmed against the frame system, panel dimensions, impact category and local code.
How much sound does a glass partition block?
A single 12mm tempered lite is around STC 35–38, adequate for general office separation. An acoustic laminate (asymmetric plies + acoustic PVB) rises to STC 40–42, and a double-glazed acoustic partition with an air cavity reaches STC 45dB or more. But the partition alone does not determine privacy: sound also travels through the frame, ceiling plenum, doors and any gaps. Achieving real acoustic privacy requires a tested system — glass, frame, head/detail and door as one assembly. Always request the full-system STC rating rather than relying on the glass value alone.
How large can a jumbo glass partition panel be?
Because most partitions are monolithic tempered (not a sealed IGU), they can use our full jumbo single-lite capacity of 3300×20000mm (11×65.6ft) where the frame and handling permit. In practice, standard office panels are far smaller — commonly 1200–1800mm wide by 2700–3600mm tall — because ceiling height, door integration and handling govern before the glass-making limit does. For floor-to-ceiling feature walls without a transom, a jumbo-height lite (up to 3300×6000mm+) can eliminate horizontal joints entirely; the frame pocket depth and deflection allowance must be engineered accordingly.
Does a glass partition need heat soak testing (HST)?
HST is strongly recommended for tempered partitions in critical or high-traffic locations — overhead panels, panels adjacent to doors, large floor-to-ceiling lites and any panel where a spontaneous break would be hazardous or costly. Testing at 554°F (290°C) for 4 hours forces nickel-sulphide inclusions to fail in the factory, reducing field breakage risk to below 0.01%. Jumbo Glass Group records a post-HST breakage rate below 0.08%, supported by SGS batch reports, EN 12150 traceability and 20-year breakage insurance. For a standard back-office panel, HST may be optional — for a flagship lobby or a panel above a reception desk, it is the sensible specification.
Send your partition layout, elevations or BIM model for a competitive FOB quotation with deflection and acoustic simulation.
Required information: Customer type (fit-out contractor / architect / developer / other) · Location & market · Partition type (office / conference / healthcare / shower / retail) · Hazardous location? (yes / no / confirm locally) · Number & size of panels (W × H) · Construction (tempered / laminated / acoustic / switchable) · Thickness preference (10 / 12 / 15 / 19mm / 12.76 / 17.52 / unsure) · Acoustic target (STC required) · Frame / system type (demountable / stick / structural) · Hardware & fittings (clamps, patch fittings, door) · Edge finish · HST required? (yes / no / unsure) · Applicable standard (EN / ASTM / AS-NZS / other) · Upload drawing (PDF / DWG / DXF / BIM) · Quantity · Destination port & incoterm · Target delivery date.
📧 tomron1688@gmail.com | 🌐 Upload drawings at www.jumbotemperedglass.com
Response: feasibility review + deflection / acoustic simulation + FOB quotation within 48 hours.
Back to the full selection-guide index.
Overhead & sloped laminated glazing — the bridge between vertical partitions and roof glazing.
Glass Skylight Selection Guide
Sloped overhead IGU glazing — thermal performance and jumbo IGU sizing.
Walkable glass floors & decks — concentrated point loads, SGP, L/500 deflection.
Showroom façades & display glazing — the commercial case-study counterpart.
The monolithic toughened lite behind most partition specifications.
PVB / SGP safety glass — post-breakage retention and acoustic builds.
Large-format overview, size capability and engineering decision flow.
Jumbo Glass Group — Selection Guides are technical references for design and specification only. Thickness, build-up, acoustic rating, fire rating and compliance must be confirmed by a qualified structural/acoustic designer and the relevant building authority for each project. Published values are typical starting points, not guaranteed design results.
Subscribe To Our Newsletter To Get Our Update News!
Copy Right © 2026 Jumbo Glass Group